Zhongshan grice strong exhaust water heater short circuit to protect your use safety


The strong row type water heater is actually USES one kind of special long heat transfer tube and the metal contact area is particularly many kind of heat exchanger, after will burn the gas heat enough to transfer the metal sheet to heat the water, thus causes the exhaust gas temperature to be extremely low, the strong row water heater has the extremely high thermal efficiency.Strong exhaust water heater wind pressure short circuit protection to better protect the safety of users.Water heater short circuit protection of wind pressure this function is indispensable.


The strong exhaust water heater is a flue gas exhaust motor added on the basis of the flue gas type, exhaust gas is discharged to the outdoor through the flue gas, when running, the flue gas is forced to be discharged to the outdoor through the flue gas, but the oxygen needed for combustion is still taken from the indoor.Strong exhaust water heater wind pressure short circuit protection to better protect the safety of users.


The forced exhaust gas water heater USES a exhaust motor set above the water heater to force smoke outward, so that the combustion exhaust is quickly removed from the outside.Through an external plug to power a gas water heater, the internal parts mainly include: pulse igniter, ion sensing probe, thermostat, wind pressure switch, insurance tube (some gas water heater), start the capacitance, exhaust air motor, micro switch, electromagnetic valve control valves, water control valves, water linkage, burner, circulating water tank, the total package circuit control, ignition lamp, the temperature display (old), gas proportioning valve (not old) and so on, the development of science to use some new technology, there are some new parts come in, slowly here lists some common parts.Strong row water heater wind pressure short circuit protection to better protect the safety of users, so it is an indispensable part.


In the case of electricity, water, ventilation, open the micro switch due to water pressure, exhaust exhaust motor start work, pulse ignitor began to discharge at the same time, the gas control solenoid valve to open the air flow through into the combustion chamber, gas in an electric spark ignites, heat circulation water tank, hot water in the cold water discharge out soon after.If the water temperature is higher than 50 degrees, limit the temperature controller to work, cut off the power and extinguish the gas.If the outdoor air pressure is too high or the flue is blocked, the long time use of the circulating water tank will lead to the melting and adhesion of the heat exchange plate of the water tank, and the exhaust is not free, the air pressure switch will turn off the power supply, and the gas water heater will stop working.Normally wind pressure switch gives fault more easily, expression is: water heater burning gas can start, but a few seconds or a few minutes with respect to automatic flameout.Water heater short circuit protection for the use of people's safety brought convenience.